honeywell water heater igniter not working

Afterward, use a screwdriver to remove the plastic face of the control valve. Check the power supply to the unit. When you click on the igniter, there should be a tiny spark happening inside of the pilot. 2 - Replace Pilot Assembly Insufficient power to the gas control valve/thermostat. ), blinking light on a different number of times, How to fix Honeywell water heater status light blinking 7 times, How to fix Honeywell water heater status light blinking 3 times, water heater shuts down due to a high temperature, Honeywell water heater light is not blinking, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. Your water heaters control knob will not turn off or move to the pilot position if it is stuck in the On position. Where can I order the parts ( Thermopile, Igniter, etc.) Today were going to talk about ways you can prevent the pilot light from going out for good and what you should do if it does go out. Dont forget to remove the bottom cover from the unit. Why does my Honeywell water heater keep shutting off? Bathroom closets are often catch-alls for anything and everything remotely related to self-care. Sediment build-up at your water tank bottom leads to premature rusting. The electronic igniter, will either light the pilot light or will light the gas directly. But when it reads below400 millivolts, be sure the thermopile is faulty, and it needs replacement. Instead, they use electronic ignition or a spark ignitor to ignite the gas. The other responsible factors of it are: When your water heaters 1 or 2 parts stop working, you will experience your Honeywell water heater with no pilot light or weak pilot light. There is more than one type of electronic ignition water heater. Your Honeywell water heaters faulty gas valve will lead to different problems. Lets start: The Honeywell heater users often complain about a major problem: the Honeywell water heater keeps turning off or wont stay lit. It may need to be replaced or re-tipped. Continue with Recommended Cookies. Either the pilot light is going out, or the pilot light is failing to start. You will have to unscrew the thermocouple, from the control valve. We will be happy to help you. Honeywell Water Heater Igniter Not Working, 7. Turn it off at the breaker panel and then on to the heat setting. The pilot lights the gas burner for the water heater. An induced draft water heater is a type of water heater that uses a small fan, to draw the combustion gas from the combustion chamber. And you will surely learn to fix your Honeywell heater issues by yourself. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. > Bad outer poor thermostat knob/gas control valve set to on position. You may have to dim the room lights in order to see . Required Part Water Heater Igniter If your hot water heater suddenly stops working, chances are a bad thermocouple has shut off the gas to the pilot light. This article discusses some problems when the lighting does not work on Honeywell water heaters. Let it be cool. However, the most standard procedure for lighting a gas water heater pilot light is as follows: Again, this process may vary slightly based on the make and model of your water heater. However, if the pilot flame will not light after you click the igniter, you need to verify that a spark is happening inside the pilot. Your heaters pilot light stops lighting when it faces restriction due to the carbon deposits build up in it. Your IP: Each of them indicates different problems. Leaks will present by creating bubbles around fittings. If you are unsure about what you are doing, do not hesitate to call a service professional. Why Is Honeywell Water Heater Status Light Not Blinking? how to fix Honeywell water heater sensor failure, How to Reset Honeywell Thermostat? That includes: The below guidelines will help to fix the tripped switch issue. Your Honeywell water heater igniter is not working due to loose igniter wiring, dirty thermopile, and bad igniter. The control board will throw a code if there is a problem with the voltage. Then, check to see if the water line is correctly connected to the heater. Remove the front access panel of your water heater. Comment and tell us whether you successfully solved your Honeywell heaters issues or not. > Verify the whiter igniter is firmly inserted into the white or orange connector. Or, the defective spark electrode itself. Use the + or - signs to change the setting. When you cant get your water heater to light, you may get a little bit irritated. If so, simply straighten the kinked tube. There are several reasons behind the no blink on the Honeywell Status light. Next, remove a screw from the bottom of the Honeywell Gas Control Valve. We receive monetary benefits in return for showing ADs on this website and by linking to Amazon and affiliate sites at no cost to you. When the gas is burned from the primary heat exchanger, the second exchanger draws heat from the exhaust. The knob can get stuck in the On/Off/Pilot position. The heater overheating can result in a burn or scald in the household. First up, check all the pipe connections of the water heater. 2. Finally, inspect and replace the broken anode rod. Repair the damage to stop beeping. Blow out the accumulated dirt from the spark button with compressed air. One possibility is that the electrical wiring to the igniter is damaged. Now if the pilot isnt lighting the burner, the water will not heat. For instance: Follow the below instruction to resolve the above igniter issues: First up, you have to check the wiring connection of the igniter. Then, move the gas control knob to Pilot position. Press the button firmly. Then, release the knob and it should pop back up. Faulty Gas Control Valves Electrical Connections. 575K views 8 years ago AO Smith Gas Water Heater This video provides step-by-step instructions for replacing the igniter and flame sensor on AO Smith gas water heaters. Then try again to relight the pilot. After going through our ultimate guide, already you know what are the common Honeywell water heater problems, their reason, and solutions. Depending on the water heater you have, it may use an igniter to ignite the gas. So, you should replace it after every 7 years. The stuck knob may cause your heater to overheat also. Here are many more reasons for water heater leaking: There are a few possible reasons why your Honeywell water heater control might not be working. Lastly, make sure you keep the white connector far from the metal pilot tube, manifold tube, and manifold door. The consent submitted will only be used for data processing originating from this website. Honeywell Ignitor - How to Replace a Water Heater Ignitor FIX IT Home Improvement Channel 98.1K subscribers Subscribe 213 65K views 8 years ago Subscribe and visit our weekly FIX IT Home. Your hot water heater may not be sparking due to a defective igniter, electrode or thermocouple. So, keep reading between the lines. One of the most common problems that can develop in older Honeywell water heaters is something referred to as a pilot light going out. Honeywell Water Heater Troubleshooting You can observe a green LED indicator on the water heater gas control when your Honeywell water heater not working. Whether your water heater is running or not, in some water heaters, the pilot light is always burning while using a minute amount of gas. It must measure at least 19.5VAC with the igniter powered. 5 Mediocre Sports Stars Who Achieved Greatness Late in Their Careers, Honeywell Water Heater Status Light Not Blinking, Zoeller Sump Pump Wont Turn On [7 Easy Solutions], Bosch Tankless Water Heater Maintenance [The Complete Guide], Igniter wires come loose from the white connector, The thermopile gets covered with carbon deposits. Either it is dirty or damaged in some way. Manage Settings If you have tried it multiple times and waited for the correct amount of time, and it is still not working, you will need to move on to the next possible issue. You will need to use your multimeter to test it. Anyway, note down some possible reasons behind the interruption in the fuel supply: Follow the below few phases to fix the gas supply issue: As for the first step, check to see if there is air in the gas line. Locate the hot surface igniter and look for a spark or glow there. She grew up surrounded by constant home improvement projects and owes most of what she knows to helping her dad renovate her childhood home. Do a special concentration to the drain valve. 7 Flashes = Gas Control Valve Failure. Now, use an adjustable wrench to unscrew the pilot tube and the gas supply tube from the control valve. What are the symptoms of a broken water heater? Improper installation of the spark rod and the pilot head. Interruption In The Gas Supply 4. Water heaters can seem a little bit intimidating since they use gas, and heat, to warm the water. link to What Kind Of Paint For Garage Walls? Also, make sure there are no flammable vapor-creating objects like paint, or gasoline nearby the heater. Now you know why the status light of your Honeywell water heater doesnt work. You will see two black connectorson the gas control valve. How long does the igniter last on water heater? Use a screwdriver to unscrew the nuts that hold the manifold door in place. This information is provided as our informed opinion and does not constitute actual advice from a licensed professional. If the igniter fails, the burner will not light. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Some people refer to this problem as a flare out or simply pilot failure. Well walk you through how to troubleshoot the issue of your water heater igniter not sparking, and educate you on possible solutions. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. If you suspect that your water tank is leaking, call a professional to repair the damage. Make sure the white igniter is snugly inserted into the white or orange connector. (Seconds! How do you light a hot water heater with an igniter Honeywell? Replace the defective one. You can email the site owner to let them know you were blocked. > Replace the bad gas control valve, & thermostat. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. One possibility is that the power to control may have been lost. The other leading reason for the low heating problems include: The Honeywell water heater is making noise because the fan has to turn on quickly to create a flow of air through the heater. > The temperature sensor detects too-high water temperature. Set the thermostat or the device's controller slightly above the current room temperature. Common solutions for: Honeywell Water heater not lighting 01 - Honeywell Water Heater Igniter Some water heaters use an igniter to ignite the gas. Step #3: Now set your multi-meter to read the voltage. As a result, it will not work the way it should. Dirt or corrosion on the spark electrode usually interferes with the flow of electricity to the pilot light and can cause it not to ignite. If you see below 400 millivolts, be sure it is defective. If still, there is no spark, inspect the spark electrode visually. You need to replace the bent or damaged electrode with the help of a qualified contractor. Induced draft water heaters use an intermittent pilot or hot surface ignition instead of a standing pilot light. Wiring issues> Ensure all the snug electrical connections to the gas control valve.Tripped thermal switch> Clean out the vents.> Reset the tripped switch. Honeywell water heater high temperature shut downyour heater and the unit stopped working. > Replace the bad electrode. Another serious problem you can often experience is yourHoneywell water heater wont ignite. The main reason for the Honeywell water heater not becoming hot enough is the malfunctioning of the thermostat. The simple resolving ways are: The Honeywell water heater knob stuck is another problem you may experience while using this heater. If the igniter fails, the burner will not light. Set your thermostat to the desired temperature. Step #5: Keep holding the knob untilthe maximum voltage is reached. Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. So, throughout this above Honeywell water heater troubleshooting guide, we well-explained all the major hitches and their solutions. The action you just performed triggered the security solution. Also, dirty pilot tubes, faulty gas valves, and clogged air vents are other possible reasons behind this. Inspect the base-ring filter and the flame arrestor to look for any dirt and debris. Hot water heaters are perhaps one of the most important things in our home. When the tank isnt properly sealed, moisture and bacteria can get into the system and cause a leak. Still, if you have any questions on any facts discussed above, dont delay to ask us through comments. Due to a loose connection of the connector, the red status light will not blink. To do this, turn the water temperature dial to Low and the On/Off/Pilot knob to Pilot. Kit includes: piezo igniter and instructions; For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater When the igniter goes bad or becomes faulty for some reason, the honeywell water heater pilot stops lighting all of a sudden. Another solution is resetting the unit by pressing and holding down both buttons for three seconds. Sometimes due to low fuel, the heater may start beeping. A broken, bent, worn-out, damaged, or a faulty thermocouple, Properly clean the thermocouple, pilot tube, and clogged air inlet, Replace the bent, broken, or defective thermocouple, tripping breaker, faulty gas valve, and malfunctioning thermostat, Turn off your heaters gas connection and allow some time to cool the thermocouple. Easy things, you will be able to work on yourself. Finally, you have to reset the tripped thermal switch to get back the element function again. In other words, you cant ignite your water heater. A Honeywell water heater will overheat if it isnt receiving enough heat from the furnace or hot water tank. How do I know if my water heater is working? Check all wiring connections. Start with inspecting the igniter wire (its either white or orange). To determine if the igniter is defective, first make sure the igniter is getting voltage. Presence of flammable vapors near the unit. At the same time as youre holding down the pilot switch, press on the piezo igniter. Another common issue with the pilot light on water heaters is that the flame frequently goes out. Replace the defective ones immediately. When your Honeywell heater stops heating, you should check the pilot light first. Turning the knob will change the water temperature in the tank. The secondary exchanger, then cools the gas vapor, until it turns into water. It should be firmly inserted into the white connector. We store towels, medicine, toiletry supplies, first-aid gear, massage devices, facial steamers, spare Painting your garage is a great way to improve the look of the space and make the walls easier to clean. Switch the knob back to the Pilot position. If there is no light, be sure dirt and debris have accumulated on the pilot assembly that is preventing lighting the burner. Most new electric igniter water heaters will have a control board. If so, simply bleeding the air from the line will resolve the issue. Set the gas control knob to PILOT. If you doing any soldering, make sure to wear protective eyewear. Check the thermostat and if it is defective, replace it with the new one. Regardless, these elements can release toxic chemicals when they burn, so you should look into having a repair done immediately. If the white or the orange igniter wire comes loose, ensure you tighten it up or insert into the white connector. If you find any wire or plug broken you can call the electrician to fix it. We will get back to you ASAP. Weve put together this guide to help you find the solution. So, lets start. If still, you are hearing the beeping noise, then try to restart the system. If this doesn't work, then it might mean that the spark electrode is defective so you will have to replace it before being able to light your pilot light again. If needed, rub the connection with sandpaper. The best part is- I will also walk you through 3 simple steps to replace the igniter if its at fault. Also, testing the thermopile reading is a must to ensure that it really needs replacement. Look through the igniter viewpoint and inspect whether it sparks or not. In case the reading is not in this range, contact your local gas supplier. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. COPYRIGHT 2023. > Replace lousy thermostat, & faulty gas control valve turned off the thermostat/control valve. Tripping this safety component is one of the most common scenarios among water heater owners. As a result, the igniter fails to ignite the burner. If this is damaged, or not working properly, you will not be able to light the pilot by pressing the igniter. Move the brush back and forth and clean the base area properly. Copyright 2022 Housetipper | ALL RIGHTS RESERVED. If the ignition fails, the water will not get hot enough. If your heaters status light wont blink, turn off the gas valve and release the gas control knob. Some water heaters use an ignition source to ignite the gas. Step #2: Disconnect thewiring connector of the thermopile from the gas control. If your electronic ignition water heater, will not light, then it could be a loose wire, the ignition may not be getting the correct voltage, or you may just need to try lighting it more than once. The board uses blinking lights, to identify which code is being thrown. The other reasons for water heater shutting down unexpectedly include: A water heater can overheat for many reasons, but the most common cause is a failure of the thermostat. If your Honeywell water heaters thermostat is bad, your heater will produce no hot water or enough hot water. I hold the pilot button in, click on the button but the status light indicator will not come on at all and theres no indication the pilot inside the tank is on. When the water pressure within the tank of a water heater reaches a steady stream, the ignition process is signaled to continue by means of a faulty pressure switch that has closed some sort of circuit. Next, reattach everything like the wiring, manifold tube, and pilot tube to the gas control valve. Jessica considers herself a home improvement and design enthusiast. In the next chapter, I will walk you through the step-by-step procedure of igniter replacement. Step 8. The other accountable factors are: Check your water heater and detect from which part it is leaking water. The water heaters safety devices are FV (Flammable Vapor) sensors. In this stage, what you need to do is to take everything out that leads into the gas control valve. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. We and our partners use cookies to Store and/or access information on a device. 2 Flashs = Thermopile low voltage. To properly and safely light your pilot light, always check the instructions first. Replace the defective pipe. How Long For A Water Heater To Heat After A Reset? The electrode should release a spark simply by pressing the piezo igniter. Whether it be identifying the problem or replacing a part, lets take a look at what you should do when your water heater igniter wont spark. Press and hold down on the gas control knob, or pilot set button. However, if you have any more struggles with any other issues with your heater, dont hesitate to let us know in the comment box. A thermocouple is an important part of your electric kitchen or gas grill. Save my name, email, and website in this browser for the next time I comment. The consent submitted will only be used for data processing originating from this website. If any of the pipes are loose, tighten them. You will need to light the igniter, with the knob in the pilot position, and then turn the knob to on after you light it. To solve this problem, use a wire brush to remove any dirt or corrosion from the inside circuit at the top of the water heater tank and try lighting it again. Heater Overheating 9. So, dont miss a single word from below. Finally, verify the igniter is working properly by relighting the pilot following the lighting instructions on the manual. Now, light the pilot using the instructions and check the status light. If it doesnt work, you need to replace the corresponding defective part. When you click the igniter to light your pilot flame, there should be a tiny spark happening inside of the pilot. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Over time, carbon and fuel residue form a layer on the thermopile. Reset the tripped thermal switch. The blinking light on a different number of times indicates that theres something up with your water heater and needs to be fixed as soon as possible. Some water heaters use an igniter to ignite the gas. If it is an intermittent pilot igniter, then you will have to make sure the pilot is lit, before turning it on. Whether it be identifying the problem or replacing a part, let's take a look at what you should do when your water heater igniter won't spark. So, whenever you start to struggle with any issue with your heater, just follow our Honeywell water heater troubleshooting guide and fix it by yourself. 12. Repair the damaged part as soon as possible. Dont miss to check the gas valve. It does not blink at all.If you could get back to me, I really would appreciate it.915-921-5951. 1 Flash = Normal Operation. The most common cause for a pilot light that repeatedly goes out on a gas water heater is a damaged, dirty, bent, or faulty thermocouple. Your water heater wont work properly if the igniter wont spark. When yourHoneywell water heater pilot light wont light, your heater will stop heating. Then, set the gas control knob to the Off position to turn off the unit. If it isn't flowing, replace the SmartValve. It will ensure a fluent gas flow. Step #4: Then, relight the pilot andhold down the gas controls thermostat knob once it is light. If you feel air flow, but no heat or cool, you likely have incorrectly configured your thermostat for a conventional system instead of a heat pump. The Honeywell water heater has 3 types of blinking lights. Many homeowners have an electronic ignition water heater because of their cheap and easy operation. Clogged base-ring filters or the flame arrestor> Clean out base-ring filters & the flame arrestor with the brush-attached vacuum cleaner. Try lighting the pilot following the lighting instructions on the water heater and visually confirm the pilot can be lit. Here are the Honeywell water heater issues explained with their easy solutions: Note: Also read to know how to fix Honeywell water heater sensor failure. Check the thermocouple. Heater No Status Light 3. Have patience when working on these things, and make sure that you are taking the correct safety precautions. Some issues caused by a bad valve are gas leaks, heaters total shutdown, heater stops working, heater blinks error codes, etc. Then, clean out the flame arrestor using a household brush. In some cases, the electronic control board is the culprit. If your pilot light still wont stay lit, the issue is almost always caused by a defective thermocouple. But they usually have a manual adjustment knob on the front. The last issue, after you have determined that there is no easy fix, is that the main control valve could be bad. How to fix Honeywell water heater status light blinking 7 times, ii. The sediment contains different chemicals and salt. Save my name, email, and website in this browser for the next time I comment. You can reset your Honeywell Water Heater in some simple ways. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. > Faulty thermostat knob, or gas control valve. Your igniter should light the gas directly if it is a hot surface ignition. Check to make sure the thermocouple connection to the control valve is tight. Wait for a while and look for any corrosion on the electrical connection. If your Honeywell water heater has no status light, our guide will prove quite effective in resolving this problem. The pilot ignites the gas burner on your water heater. Other reasons for this problem are: There are a few possible causes for a malfunctioning Honeywell water heater igniter. If there is no spark, be sure it is not getting the voltage. It may also be caused due to a failing pressure switch. Over time the mineral builds up on your gas water heaters bottom area. An example of data being processed may be a unique identifier stored in a cookie. Now, inspect the pressure relief valve for the stuck debris inside of it. To determine if the igniter is defective, first make sure the igniter is getting voltage. Chances are there may be an easy fix or a fix that you can do yourself, without calling in a plumber. Honeywell Water Heater Keeps Turning Off, 5. Click to reveal Another possibility is that there is something blocking the igniters contact with the wire coil in the furnace. When you hold down the pilot switch on a gas heater and click the igniter button repeatedly, a small spark should ignite the pilot. We need them to do laundry, take showers, clean dishes, and much more. 5 Flashes = Sensor Failure. How to do Honeywell water heater adjustment? Now look for loose wiring to the switch, which is leading the switch to trip unexpectedly. When your water heaters pilot light goes out, automatically, your heater will shut off by itself. Why does my water heater pilot light keep going out? If it is flowing, measure the voltage between the 24V Hot and 24V Common leads to the SmartValve. Verify the water pipes are properly insulated and ventilated. Thenswitch the dial to very hot for 10 seconds. Also, connect the black lead to the white wire. Attach the red positive lead to the red thermopile wire. Warning. As it is a safety device, it prevents turning on the gas valve if it gets defects. Another reason for water heater leaks is the tank not being properly sealed. When this happens, your burners wont ignite, and your homes water will be freezing cold. All Right Reserved by HeaterFixLab. Pilot lights, but the main burner doesn't come on. Just follow the below simple steps I described below to make the replacement correctly: First off, turn the main gas supply valve clockwise to stop the gas supply to the unit. An example of data being processed may be a unique identifier stored in a cookie. Your heaters burner fails to ignite mainly for the following factors: For fixing the above difficulties, the easy resolving ways are: Honeywell water heater overheatingis one of the potentially dangerous issues with your gas water heater. If the power still isnt working, try to replace the igniter. Bad thermopile or defective igniter are the two main culprits that cause the status light to not blink. Also, make sure that every heating element is in good working condition. Using oil will ruin the valve and damage the seal. The furnace gas valve for this type of furnace is identifiable with its solenoid designations: MV (main valve), PV (pilot valve), and PV/MV (common). The main reason for the Honeywell water heater not becoming hot enough is the malfunctioning of the thermostat. Also, this guide has the solutions to other hitches like the heater not heating, overheating; the burner wont ignite, error codes, etc. Then, look for any broken or burnt-out heating element. A typical issue with a thermostat is that it may be over-saturated or dirty and not working effectively. Then go for the other solutions below: Due to the Honeywell water heaters flammable vapor sensor lockout, your heater stops heating water. > Replace the bad gas control valve, thermostat knob, faulty outer door, weak pilot, and faulty thermostat to ensure proper gas supply to the heater. Clean the thermocouple and replace it if needed. This troubleshooting guide will explain all those factors responsible for your Honeywell water heaters major problem and their practical solutions. You will need to know whether your hot water heater uses an intermittent pilot, or a hot surface ignition so that you can properly address the issues with the igniter. Hold down the knob in this position. Replacement is an easy DIY repair. If this is defective and does not work properly, it can cause the ignition process to stall at certain junctures within the said process, preventing the water heater from turning on. Your Honeywell water heater can leak from the bottom due to the improperly maintained drain valve. If the FV sensor detects any issue near the heater, it will prevent your heaters ignition possibility by going into lockout mode. If its a Honeywell water heater, follow the steps I mentioned to make the replacement with ease.